Changelog
ATTENTION: Settings can often be wiped when a new firmware is released. Check the upgrade guide for more information
12/11/24: Firmware 0.6.3 released
- Fix inaccuracy with Quantizer
- Fix display issue with rendered Quantizer note
08/11/24: Firmware 0.6.2 released
- Fix issue with MD-002 Gin Play/Rec button handling
08/08/24: Firmware 0.6.1 released
- Fix crash when clearing channel and envelope or random morph parameter is selected
- Fix issue envelope skew/decay indexing
05/08/24: Firmware 0.6.0 released
- Added Lorenz chaos waveform
- Added Operand advanced parameter
- Reworked Quantizer with support for 8 custom scales, better modulation system and a new key editor
- Random waveform reworked to support new Blend parameter
- Phase retriggering added
- Copy Paste channel functionality added
- Amplitude and Offset units now in terms of voltage rather than percentage
- Added Select Tap window setting
- UI/UX improvements to settings
- Encoder responsiveness improvements
07/05/24: Firmware 0.5.3 released
- Add small delay on bootup before initialising SD card
28/03/24: Firmware 0.5.2 released
- Fix offset in unipolar mode
06/03/24: Firmware 0.5.1 released
- Fix hang when rebooting Juniper while Gin is connected (update for Gin available 0.1.4)
- Fix Gin Updater
29/02/24: Firmware 0.5.0 released
- Add new waveforms,
Tan
andStair-step
- Rework
Sin
morph - 4 quadrant multiplication / polarization / inversion modulation added.
Amplitude
now ranges from +100 to -100 - Support for fractional (1/10th) BPM synchronization. Available from the
SYSTEM
settings - Fix a serious recorder overdub bug, along with some fixes to Gin
- Rework the CV input to handle bipolar and unipolar signals better
- Optimized power consumption & heat dissipation
- Improved error handling
- Other small fixes
- Add new waveforms,
23/01/24: Firmware 0.4.6 released
- Optimize recorder resulting in faster read speeds
- Improve
Reset Mode
(formally known asRun Reset
) - Numerous fixes for waveform modulation UX
- Function generator mode will now return to 0.0V after the cycle ends
- Improved error reporting and handling
28/12/23: Firmware 0.4.5 released
- Improved responsiveness of envelope waveform
- Phase now modifiable when frequency modulating (applicable for
Function Generator
mode) - Fix phase offset bug in
Function Generator
mode - Fix sample & hold negative threshold
- Other small fixes
03/11/23: Firmware 0.4.4 released
- Fixes to trigger logic
Time
modulation is now inverted in relation toFrequency
- Smarter wiping of user data when upgrading firmware
27/10/23: Firmware 0.4.3 released
- Rework
Random
waveform morph logic for stair-step and slew - Greatly improve
Frequency
fine / course parameter changes - Fix
Mix
and fine / course parameter changes - Reduce duration to switch between fine / course modes
- Tweak
Exp
waveform exponent
- Rework
20/10/23: Firmware 0.4.2 released
- Fix quickslot assign issue when assigning quick-slot to top item in the list
10/10/23: Firmware 0.4.1 released
- Improve DAC reliability
- Fix an issue with default states
09/10/23: Firmware 0.4.0 released
- Frequency can now be de-synchronized, allowing for a range of 1mHz to 128Hz
- Input Focus now supports modulation
- Added trigger support. Channels can now be triggered by an external CV source, or any of the other internal channels
- “Envelope” waveform replaces the “Exp” and R.Exp” waveforms
- Course and fine grain mode for parameter changes has been added
- Added state management. States are saved directly to the SD Card
- States can be recalled with “Quick-slots”, up-to 8 quick-slots can be used
- Added recorder links
- Unipolar mode amplitude now scales from 0% to make it more appropriate for feeding unipolar CV to VCAs and alike
- Random waveform now respects the Phase setting
- Fixed modulation inconsistencies
- Added screensaver
- Lots of smaller fixes and optimizations
06/08/23: Firmware 0.3.2 released
- Recorder trigger fixes and improvements
- Rework run modes and reset logic, added run gate latch
- GUI fixes
24/07/23: Firmware 0.3.1 released
- Full MD-002 Gin capability
- Added recorder bar progress UI indicator
- Much improved recorder streaming and error handling
- Added new SYSTEM menu
08/05/23: Firmware 0.2.3 released
- Added Recorder overdub capability
- Improved Recorder UI indicators
- Recorders using dynamic length recordings can now reach a maximum of 65536 bars
- Added performance mute mode
- Added new “modulation selector” for Waveform and Morph: allows the user to select discrete values to modulate between
- Added “Inverter” advanced function
- Added “Output” waveform
- Added “Input Focus” functionality, allowing to adjust input behaviour for improved reusability
- Improved control responsiveness
- Fix a synchronization issue with continuous recorder modes using non-integer record lengths/bpms
- Fix an issue with phase synchronization
- Fix BPM detect issue for asymmetric clocks
- Added initial support for MD-002
- Other small fixes and improvements
- ➡️ Please note when upgrading from 0.1.x to 0.2.x, it is advised to reformat the SD Card. See docs for details.
01/03/23: Firmware 0.1.5 released
- Added dynamic recorder lengths, quantized to a 4/4 time signature
- Added “goto modulator” channel shortcut
- Added “goto previous” channel shortcut
- Improved external clock detection
26/11/22: Firmware 0.1.4 released
- Added Wavefolder, accessible as an advanced function
- The Sample and Hold (S&H) unit now can be configured for either traditional sampling or tracking (T&H)
- Fix issues with Phase synchronization, added Phase modulation
- Channel select within Parameter menus are now highlighted with brighter LEDs
- Added button shortcuts for changing the parameter while in the parameter menu
02/11/22: Firmware 0.1.3 released
- Fix an issue in the recorder when using single-shot mode
- Adjust timings of channel select overlays
26/10/22: Firmware 0.1.2 released
- Increase maximum record duration to 255 bars
- Settings of a channel can now be modified during recorder playback
- Many useability improvements to controls, overlays and menus
- Bug fixes
06/10/22: Firmware 0.1.1 released
- Single-shot and continuous mode recorders, along with better trigger support
- Modulation enhancements, including an additional offset parameter
- Sample & hold improvements and fixes
- Improve GUI overlays
- Bug fixes
15/09/22: MD-001 Juniper is now available
14/08/22: The first production run of MD-001 Juniper underway 🎉
24/04/22: MD-001 closed beta begins
18/03/22: Announcing MD-001 Juniper: an 8 channel synced modulation source in 8HP. Coming in Q1 2022.